ML-ACR Automatic Charging Relay with Manual Control - 12V DC 500A
  Zoom
ML-ACR Automatic Charging Relay with Manual Control - 12V DC 500AML-ACR Automatic Charging Relay with Manual Control - 12V DC 500AML-ACR Automatic Charging Relay with Manual Control - 12V DC 500A

ML-ACR Automatic Charging Relay with Manual Control - 12V DC 500A

£289.99 Save £73.60 (RRP £363.59)  
+

Part Number:  7622
Brand:  Blue Sea

Availability:  

Standard UK Delivery for this Product is 4-5 days.

500 Amp magnetic latching (bi-stable) relay automatically combines batteries during charging and isolates batteries when discharging and when starting engine

  • Manual control switch provides an added level of safety allowing control with or without power, and offering LOCK OFF capability for servicing
  • Includes ML-Series Remote Control Contura Switch PN 2146
  • Automatically manages the charging of two large battery banks
  • Allows paralleling of battery banks for emergency starting
  • 500 Ampere continuous rating to support high-output alternators
  • Magnetic Latch (ML)—ACR draws very low current (<40mA to monitor terminal voltage) in the 'ON' or 'OFF' states, and draws moderate current for very short time when changing state
  • Dual sensing—senses charge on both battery banks
  • Start Isolation (SI)—can be configured for temporary isolation of House loads from Engine circuit during engine cranking to protect sensitive electronics
  • Engine Isolation (EI)—can be configured for isolation of two engines while both are running to protect engine electronics and maximize alternator output
  • Senses charging on two battery banks
  • LED output to remotely indicate when batteries are combined, isolated, in voltage lockout, or in Start or Engine isolation
  • 3/8'-16 tin-plated copper studs for maximum conductivity and corrosion resistance
  • 7/8' (22mm) stud length accepts multiple cable terminals
  • Silver alloy contacts provide high reliability for switching live loads
  • Label recesses for circuit identification

Specifications

Control Circuit Connection 

Tinned Wire

Nominal Voltage

12V DC

Manual Control 

Yes

Engine Isolation 

Yes

Mounting

#10

Start Assist 

Yes

Start Isolation 

Yes

Amperage Operating Current

13mA 

Amperage Operating Current when changing state

<7.0A

Terminal Stud Torque

140 in-lb (15.82 Nm)

Continuous Rating 

500A

Intermittent Rating 

700A (5 min)

Cranking Rating 30 sec 

1450A DC

Minimum Operating Temperature

-10° C

Maximum Operating Temperature

60° C

Cable Size to Meet Ratings

4/0 AWG x 2

Live Current Switching

300A @ 12V DC

Stud Material

Tinned Copper

Switching Cycles

100000

Terminal Ring Diameter Clearance

1.12in (28.45 mm)

Terminal Stud Length

1.50in (38.1 mm)

Terminal Stud Size

3/8' - 16 (M10)

Wire Size

20 AWG

Relay Contact Position

Combine 30 sec

13.5V

Combine 90 sec

13.0V

Open 10 sec

12.35V


Please see our COVID-19 response here